Moments of Inertia of Roof sheets
Type | t = 0.63 mm | t = 0.75 mm | t = 0.88 mm | t = 1.00 mm | t = 1.13 mm | t = 1.25 mm | t = 1.50 mm |
---|---|---|---|---|---|---|---|
SAB18/988 | 25 | 30 | 36 | 41 | |||
SAB27/1000 | 59 | 71 | 85 | 97 | |||
SAB42/960 | 178 | 221 | 252 | ||||
SAB19/1050 | 37 | 46 | 55 | 63 | |||
SAB30/1100 | 52 | 66 | 82 | 98 | |||
SAB35/1035 | 94 | 120 | 149 | 176 | |||
SAB40/915 | 139 | 176 | 219 | 260 | |||
SAB45/900 | 228 | 288 | 355 | 420 | |||
SAB50/1000 | 184 | 232 | 288 | 342 | |||
SAB19KD/1050 | 38 | 46 | 55 | 63 | |||
SAB30KD/1050 | 77 | 98 | 122 | 142 | |||
SAB45KD/1000 | 130 | 162 | 192 | 219 | |||
SAB58KD/945 | 197 | 285 | 360 | 429 | |||
SAB35R/1035 | 158 | 192 | 224 | 282 | |||
SAB40R/915 | 248 | 293 | 335 | 423 | |||
SAB50R/1000 | 314 | 383 | 448 | 579 | |||
SAB70R/800 | 796 | 972 | 1118 | 1410 | |||
SAB85R/1120 | 849 | 1038 | 1217 | 1416 | 1572 | 1897 | |
SAB89R/915 | 1078 | 1289 | 1479 | 1679 | 1864 | ||
SAB100R/825 | 1488 | 1760 | 2012 | 2536 | |||
SAB106R+/750 | 1866 | 2198 | 2503 | 3144 | |||
SAB110R/1000 | 1484 | 1796 | 2084 | ||||
SAB135R/930 | 3230 | 3540 | 3830 | 4350 | 4830 | 5830 | |
SAB153R/840 | 3750 | 4340 | 4890 | 5560 | 6170 | 7440 | |
SAB158R/750 | 4760 | 5360 | 5910 | 6710 | 7450 | 8990 | |
SAB200R/750 | 7723 | 9015 | 10189 | 12114 | 13891 | 16761 | |
SAB200R/840 | 6460 | 7728 | 8916 | 10221 | 11439 | 14014 |