XBeam2D Loads: Difference between revisions
(Created page with "frameless|969x969px Every load (node load, beam load or node displacements) are inserted per load case. Load cases Beam load Node load Node displacement === Input of the load cases === frameless|588x588px '''No.''' This number is generated automatically. You can not change this number '''Description''' Free text to describe the load case '''Type''' The type of load. Dependent on the type of load,...") |
No edit summary |
||
Line 1: | Line 1: | ||
[[File:XBeam2DRibbonLoads.png|frameless|969x969px]] | [[File:XBeam2DRibbonLoads.png|frameless|969x969px]] | ||
Revision as of 12:51, 5 September 2022
Every load (node load, beam load or node displacements) are inserted per load case.
Load cases
Beam load
Node load
Node displacement
Input of the load cases
No.
This number is generated automatically. You can not change this number
Description
Free text to describe the load case
Type
The type of load. Dependent on the type of load, standard combination factors psi0, psi1, and psi2 are determined according to the Eurocode.
These combination factors are offered as a standard by entering the load combinations. However, these values can be adapted.
Automatically two load combinations are generated. Permanent and variable loads.
Automatically generate combinations
When you enter/change load combinations, the load combinations are automatically generated. You can also change these combinations and expand them.
Sequence load cases
With a click on the right mouse button, the context menu shown below is opened. With these functions you can easily adapt the sequence of the load cases and/or insert load cases.
Insert
A new load case is created, and inserted above the current load case.
Delete
The load case is deleted, including all the loads
Copy
The load case is copied, including all the loads
Move up/ move down
A load can be moved up and down a line.
Copy loads from..
Every load from an already existing load case can be copied. The dialog box shown below is opened. Herein you choose the load case from which you want to copy the loads.
Load combinations
No.
This number is automatically generated. You can not change this number.
Description
Free text space to describe the load combination
Type
The type of load (ULS - ultimate limit state, ULS- fire, SLS-serviceability limit state, quasi permanent). Dependent on the type of combination, standard values for the combination factors (psi) and the load factor (gamma) are offered according to the Eurocode. But these values can be adapted.
Columns with load cases
For all the load cases, columns are created. In that way, a table appears in which all the combinations are shown. Every cell contains 2 values in the syntax : combination factor x load factor.
When you click on the cell the following dialog box appears. Here you can adapt both values.
For the combination factor and the load factor combo-boxes are offered including the standard values from which you can choose. You can also insert an own value. This gives a lot of freedom. If you for instance take one of the values as zero, the product of the two values obviously is zero as well. In that case the cell is showed 'empty'. This is only to make things clear.
Standard there are three load combinations generated. (ULS (6.10a), ULS (6.10b) and SLS)
Sequence load combinations
With a click on the right mouse button, the context menu shown below is opened. With these functions you can easily adapt the sequence of the load cases and/or insert load cases.
Insert
A new load combination is created and inserted above the current load case.
Delete
The load combination is deleted.
Copy
The load combination is copied.
Move up/ move down
A load combination can be moved up and down a line.
Copy ULS combination to SLS
Every load combination of the type ULS will be copied as type SLS. The load factors are set to 1.