XBeam2D Loads: Difference between revisions
(Created page with "frameless|969x969px Every load (node load, beam load or node displacements) are inserted per load case. Load cases Beam load Node load Node displacement === Input of the load cases === frameless|588x588px '''No.''' This number is generated automatically. You can not change this number '''Description''' Free text to describe the load case '''Type''' The type of load. Dependent on the type of load,...") |
No edit summary |
||
(11 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
[[ | [[Documentation XBeam2D|BACK]] | ||
===Beam Loads=== | |||
Beam loads are inserted in a local beam coordinate system. See [[Struct4U Design Arrangements | Design arrangement.]] | |||
[[File:XBeam2DBeamLoads1.png|frameless]] | |||
'''The dialog box shown below is opened.''' | |||
[[File:XBeam2DBeamLoads2.png|none|frame]] | |||
'''Load case''' | |||
Choice for the load case. Here you can directly insert a new load case. | |||
'''Type of load''' | |||
Choose the type of load you want to add. | |||
{| class="wikitable" | |||
|- | |||
!Type!!Description | |||
|- | |||
|[[File:load-q.png|20 px|Wikipedia encyclopedia|link=http://68.183.11.126/index.php/File:Load-q.png]]||Even distributed load, or varying load | |||
|- | |||
|[[File:Load-F.png|20 px|Wikipedia encyclopedia|link=http://68.183.11.126/index.php/File:Load-F.png]]||Point force - F-load | |||
|- | |||
|[[File:Load-M.png|20 px|Wikipedia encyclopedia|link=http://68.183.11.126/index.php/File:Load-M.png]]||Moment - M-load | |||
|}'''q1''' | |||
The magnitude of the load. For the q-load the magnitude of the load at the beginning in kN/m. For a point load the amplitude of the load in kN. For a moment the magnitude of the load in kNm. | |||
With plus min you can change the sign of the loads very easy. Standard the sign is at min because this is most common. | |||
''' | '''q2''' | ||
Only for the q-load the magnitude of the load at the end in kN/m. | |||
'''a''' | |||
The distance in mm where the load starts, counted from the begin node of the beam. | |||
'''L''' | |||
Only for the q-load the length of the load should be inserted. Standard the load is going up to the end of the beam. | |||
''' | '''Angle''' | ||
Only for the q- and F-load. The angle in degrees to the perpendicular. The direction opposite to the clockwise direction is positive. | |||
''' | '''Beam angle''' | ||
The | The angle in degrees with the global x-axis. The direction opposite to the clockwise direction is positive. With | ||
[[File:XBeam2DBeamLoads4.png]] | |||
You can take over the angle from the previous section. | |||
''' | '''z''' | ||
The | The distance in the z-direction in mm relative to the reference line. The reference line is adjustable. 'z relative to top', 'z relative to centerline', 'z relative to bottom'. | ||
This distance is only relevant for lateral-torsional buckling resistance check . | |||
'''Table''' | |||
Beam loads can also be added/changed in the table. It does not matter. It is also possible to change in between graphical input and numerical input via tables. | |||
[[File:XBeam2DBeamLoads5.png|none|frame]] | |||
[[File: | |||
Latest revision as of 08:52, 12 November 2022
Beam Loads
Beam loads are inserted in a local beam coordinate system. See Design arrangement.
The dialog box shown below is opened.
Load case
Choice for the load case. Here you can directly insert a new load case.
Type of load
Choose the type of load you want to add.
Type | Description |
---|---|
Even distributed load, or varying load | |
Point force - F-load | |
Moment - M-load |
q1
The magnitude of the load. For the q-load the magnitude of the load at the beginning in kN/m. For a point load the amplitude of the load in kN. For a moment the magnitude of the load in kNm.
With plus min you can change the sign of the loads very easy. Standard the sign is at min because this is most common.
q2
Only for the q-load the magnitude of the load at the end in kN/m.
a
The distance in mm where the load starts, counted from the begin node of the beam.
L
Only for the q-load the length of the load should be inserted. Standard the load is going up to the end of the beam.
Angle
Only for the q- and F-load. The angle in degrees to the perpendicular. The direction opposite to the clockwise direction is positive.
Beam angle
The angle in degrees with the global x-axis. The direction opposite to the clockwise direction is positive. With You can take over the angle from the previous section.
z
The distance in the z-direction in mm relative to the reference line. The reference line is adjustable. 'z relative to top', 'z relative to centerline', 'z relative to bottom'.
This distance is only relevant for lateral-torsional buckling resistance check .
Table
Beam loads can also be added/changed in the table. It does not matter. It is also possible to change in between graphical input and numerical input via tables.