XBeam2D XFrame2D Load Combinations: Difference between revisions
(Created page with "===Load combinations=== frameless|830x830px|link=http://68.183.11.126/index.php/File:XBeam2DLoadCombinations.png '''No.''' This number is automatically generated. You can not change this number. '''Description''' Free text space to describe the load combination '''Type''' The type of load (ULS - ultimate limit state, ULS- fire, SLS-serviceability limit state, quasi permanent). Dependent on the type of combination, standard v...") Â |
Rob-Struct4u (talk | contribs) (→â€)  |
||
Line 4: | Line 4: | ||
'''No.''' | '''No.''' | ||
This number is automatically generated. You | This number is automatically generated. You cannot change this number. | ||
Line 22: | Line 22: | ||
When you click on the cell the following | Â | ||
When you click on the cell the following dialogue box appears. Here you can adapt both values. | |||
[[File:XBeam2DLoadCombinations2.png|frameless|link=http://68.183.11.126/index.php/File:XBeam2DLoadCombinations2.png]] | [[File:XBeam2DLoadCombinations2.png|frameless|link=http://68.183.11.126/index.php/File:XBeam2DLoadCombinations2.png]] |
Latest revision as of 14:08, 26 October 2022
Load combinations
No.
This number is automatically generated. You cannot change this number.
Description
Free text space to describe the load combination
Type
The type of load (ULS - ultimate limit state, ULS- fire, SLS-serviceability limit state, quasi permanent). Dependent on the type of combination, standard values for the combination factors (psi) and the load factor (gamma) are offered according to the Eurocode. But these values can be adapted.
Columns with load cases
For all the load cases, columns are created. In that way, a table appears in which all the combinations are shown. Every cell contains 2 values in the syntax : combination factor x load factor.
When you click on the cell the following dialogue box appears. Here you can adapt both values.
For the combination factor and the load factor combo-boxes are offered including the standard values from which you can choose. You can also insert an own value. This gives a lot of freedom. If you for instance take one of the values as zero, the product of the two values obviously is zero as well. In that case the cell is showed 'empty'. This is only to make things clear.
Standard there are three load combinations generated. (ULS (6.10a), ULS (6.10b) and SLS)
Sequence load combinations
With a click on the right mouse button, the context menu shown below is opened. With these functions you can easily adapt the sequence of the load cases and/or insert load cases.
Insert
A new load combination is created and inserted above the current load case.
Delete
The load combination is deleted.
Copy
The load combination is copied.
Move up/ move down
A load combination can be moved up and down a line.
Copy ULS combination to SLS